Outsulation Plus/Outsulation Plus NC Details (FR_DSC110NC)
An Exterior Insulation and Finish System
Print
Version in PDF Format (2,335 KB)
Table Of Contents:
| Description | PDF File |
| Cover Sheet | |
| Table Of Contents | |
|
System Details |
PDF File |
| Outsulation Plus System | OPL 0.0.01 |
| Foundation With Drainage Track™ | OPL 0.0.02 |
| Foundation With Drainage Strip™ | OPL 0.0.03 |
| Grade Level Termination At Concrete Curb | OPL 0.0.04 |
| Head/Sill | OPL 0.0.05 |
| Head/Sill For Self Flashing Window Option | OPL 0.0.06 |
| Window Head J-Track Option Self Flashing Window | OPL 0.0.07A |
| Protection For Rough Openings | OPL 0.0.07B |
| Opening Preparation For Self Flashing Type Window Option- 1 | OPL 0.0.08 |
| Opening Preparation For Self Flashing Type Window Option- 2 | OPL 0.0.09 |
| Window Head J-Track Option Store Front Window | OPL 0.0.10 |
| Opening Preparation For Store Front Type Window Option | OPL 0.0.11 |
| Jamb | OPL 0.0.12 |
| Parapet - Cap Flashing | OPL 0.0.13 |
| Parapet/ Wall Termination | OPL 0.0.14 |
| Parapet - Solid Substrate | OPL 0.0.15 |
| Soffit/Fascia Intersection | OPL 0.0.16 |
| Soffit - Uninsulated | OPL 0.0.17 |
| Inside/Outside Corners | OPL 0.0.18 |
| Outside Corner - High Impact | OPL 0.0.19 |
| Horizontal Expansion Joint | OPL 0.0.20 |
| Horizontal Slip Joint | OPL 0.0.21 |
| Expansion Joint Options | OPL 0.0.22 |
| Structural Expansion Joints | OPL 0.0.23 |
| Penetrations | OPL 0.0.24 |
| Wall Penetrations | OPL 0.0.25 |
| Sign Attachment | OPL 0.0.26 |
| Aesthetic Reveals | OPL 0.0.27 |
| Projecting Graphics | OPL 0.0.28 |
| Recessed Graphics | OPL 0.0.29 |
| Horizontal Joint At Stone Veneer | OPL 0.0.30 |
| Horizontal Joint At Stucco | OPL 0.0.31 |
| Horizontal Joint At Wood Siding | OPL 0.0.32 |
| Soffit Vent | OPL 0.0.33 |
Dryvit makes no representation regarding conformity of its suggestions to model building codes, engineering criteria, specific applications or project locations. All components indicated in illustrations, as well as others that may be required for the integrity of the system shall be designed, detailed and engineered by representatives of the architect, owner or contractor to be in conformance with model codes, architectural and engineering requirements pertaining to specific building projects.
Dryvit makes no warranty, expressed or implied, as to the architectural design, engineering or workmanship of projects utilizing Dryvit systems or products.
The liabilities of Dryvit Systems Canada shall be as stated in the Outsulation Plus Limited Commercial Warranty. Contact Dryvit Systems Canada for a full and complete copy of the Warranty.
R5: 07/2008