M21: Insulation With Render Finish Printer Friendly Version In PDF Microsoft® Excel Version |
Quantity Surveyors: Print the BoQ Guidance Document (DUK689) in order to use the Guidance Bill of Quantities below. |
|
PAGE |
REF |
DESCRIPTION |
QTY |
UNIT |
RATE |
TOTAL |
|
GENERALLY |
||||||
|
A |
These generic Bills of Quantities have generally been prepared in accordance with the Standard Method of Measurement, SMM7 edition revised 1998 incorporating Amendments 1 and 2. In certain instances it has been considered necessary to depart from the rules of the SMM to fully reflect the costs involved in the proper execution of the works |
|||||
|
B |
No attempt has been made in these Bills of Quantities to include items for Preliminaries/General Conditions, etc., as these will very much depend on the type of contract and location and will vary considerably from project to project |
|||||
|
C |
Dryvit System applications are to be carried out by a Specialist Installer participating in the Dryvit Applicator Training Programme [one operative on site must be trained to Level 3 Supervisor] |
|||||
|
|
M20: EXTERNAL RENDERED COATING SYSTEM |
|||||
|
System; Dryvit ACR 50; external anti-crack render system: [re-profiling mortar (optional) Stucco Plus with Prymit primer/curing agent, nominal 10 thick]; finish/es PMR with Colorprime, texture [Sandpebble], colour [from standard range];to be obtained and in accordance with the general requirements of Dryvit UK Ltd., Unit 4, Wren Park, Hitchin Road, Shefford, Bedfordshire, SG17 5JD, Tel:01462 819555, Fax: 01462 819556, ukenquiries@dryvit.com all as specification clauses M20: 160E & 810A |
||||||
|
Walls on [brickwork, blockwork, concrete, over existing render or over painted substrate] |
||||||
|
D |
|
m2 |
||||
|
E |
|
m |
||||
|
Walls, patterned to imitate ashlar facing with feature groove [10mm wide and 6mm deep], on [brickwork, blockwork, concrete over existing render or over painted substrate] |
||||||
|
F |
|
m2 |
||||
|
G |
|
m |
||||
|
Soffits on [concrete over existing render, or over painted substrate] |
||||||
|
A |
|
m2 |
||||
|
B |
|
m |
||||
|
Soffits 3.50 - 5.00m above floor, on [concrete over existing render or over painted substrate] |
||||||
|
C |
|
m2 |
||||
|
D |
|
m |
||||
|
Isolated beams on [concrete over existing render or over painted substrate] |
||||||
|
E |
|
m2 |
||||
|
F |
|
m |
||||
|
Isolated columns on [concrete over existing render or over painted substrate] |
||||||
|
G |
|
m2 |
||||
|
H |
|
m |
||||
|
Features; Dryvit Pre-fabricated Architectural mouldings |
||||||
|
I |
|
m |
||||
|
J |
|
m |
||||
|
K |
|
m |
||||
|
Dryvit [powder coated aluminium or stainless steel] corner (angle) beads as M20:632A and 640A |
||||||
|
L |
|
m |
||||
|
Dryvit [powder coated aluminium or stainless steel] stop bead (90°) as M20:632A and 640A |
||||||
|
M |
|
m |
||||
|
Dryvit [powder coated aluminium or stainless steel] bellcast bead as M20:632A and 640A |
||||||
|
A |
|
m |
||||
|
Dryvit [powder coated aluminium] movement bead working as M20:632A, 640A and 650A |
||||||
|
B |
|
m |
||||
|
Construction movement joints as M20:650A and 947A using Dryvit 1 low modulus silicone sealant |
||||||
|
C |
|
m |
||||
|
Sealant joints to M20:947A work Dryvit 1 low modulus silicone sealant as Z22 |
||||||
|
D |
|
m |
||||
|
TOTAL TO SUMMARY £ |
|
Please note that this guidance bill section should be read in conjunction with the current Dryvit Bill of Quantities Guidance Document and the Specifier's M20 work section produced with the aid of the Dryvit NBS Specification.
R1:02-19-2001